5
Hall Research DS Manager
Command Purpose Reply Notes
<^B>GFE<CR> Get Modules
MAC Address
<^B> xxx.xxx.xxx.xxx.xxx.xxx<CR>
Where xxx.xxx.xxx.xxx.xxx.xxx
represents the MAC Address
<^B>SFExxx.xxx.xxx.xxx.xxx.xxx<CR>
Where xxx.xxx.xxx.xxx.xxx.xxx represents the
MAC Address
Set Modules MAC
Address
<^B>A<CR>
1
st
Digit must
be EVEN.
Must
REBOOT for
changes to
take effect
It is
recommende
d that the
MAC address
not be
changed
<^B>GIP<CR> Get Modules IP
Address
<^B>Aaaa.bbb.ccc.ddd<CR>
Where aaa.bbb.ccc.ddd represents
the IP Address
<^B>SIPaaa.bbb.ccc.ddd<CR>
Where aaa.bbb.ccc.ddd represents the IP Address
Set Modules IP
Address
<^B>A<CR>
Must
REBOOT for
changes to
take effect
<^B>GPN<CR> Get Modules Port
Number
<^B>Aaaaaa <CR>
Where aaaaa represents the Port
Number from 0 to 65534
Defaults to
1001
<^B>SPNaaaaa<CR>
Where aaaaa represents the Port Number
Set Modules Port
Number
<^B>A<CR>
Must
REBOOT for
changes to
take effect
<^B>GGI<CR> Get Modules
Gateway Address
<^B>Aaaa.bbb.ccc.ddd<CR>
Where aaa.bbb.ccc.ddd represents
the Gateway Address
<^B>SGIaaa.bbb.ccc.ddd<CR>
Where aaa.bbb.ccc.ddd represents the Gateway
Address
Set Modules
Gateway Address
<^B>A<CR>
Must
REBOOT for
changes to
take effect
<^B>GNM<CR> Get Modules
SubNet Mask
<^B>Aaaa.bbb.ccc.ddd<CR>
Where aaa.bbb.ccc.ddd represents
the SubNet Mask
<^B>SNMaaa.bbb.ccc.ddd<CR>
Where aaa.bbb.ccc.ddd represents the SubNet
Mask
Set Modules
SubNet Mask
<^B>A<CR>
Must
REBOOT for
changes to
take effect
<^B>GBR<CR> Get Modules
Baud Rate
<^B>Aaa <CR>
Where aa represents the Baud Rate
as follows:
0 = 1200 5 = 38400 10 = 600
1 = 2400 6 = 57600 11 = 28800
2 = 4800 7 = 115200
3 = 9600 8 = 150
4 = 19200 9 = 300
<^B>SBRaa<CR>
Where aa represents the Baud Rate as follows:
0 = 1200 5 = 38400 10 = 600
1 = 2400 6 = 57600 11 = 28800
2 = 4800 7 = 115200
3 = 9600 8 = 150
4 = 19200 9 = 300
Set Modules
Baud Rate
<^B>A<CR>
Must
REBOOT or
LOG OUT for
changes to
take effect
<^B>GPR<CR> Get Modules
Parity
<^B>Aaa <CR>
Where aa represents the Parity as
follows:
0 = Off or None
1 = Even
2 = Odd
3 = Mark
4 = Space